Silicon Labs /SiM3_NRND /SIM3L166_C /ACCTR_0 /LCCONFIG

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as LCCONFIG

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (LOW)PEMD 0CMP0FTH 0CMP0CTH0 (LOW)CMP0THR 0CMP1FTH 0CMP1CTH0 (LOW)CMP1THR 0 (0_MV)CMPLHYS 0 (0_MV)CMPHHYS 0 (5_US)CMPMD 0 (DISABLED)CMP0CNT1EN 0 (DISABLED)FCMP0EN 0 (DISABLED)FCMP1EN

PEMD=LOW, CMPHHYS=0_MV, CMPMD=5_US, CMP1THR=LOW, CMPLHYS=0_MV, FCMP1EN=DISABLED, CMP0THR=LOW, FCMP0EN=DISABLED, CMP0CNT1EN=DISABLED

Description

LC Configuration

Fields

PEMD

LC Pulse Extension Mode.

0 (LOW): Stretch the LC comparator output low pulses by approximately 20 ns.

1 (HIGH): Stretch the LC comparator output high pulses by approximately 20 ns.

2 (NONE): No pulse extension.

CMP0FTH

LC Comparator 0 Fine Threshold.

CMP0CTH

LC Comparator 0 Coarse Threshold.

CMP0THR

LC Comparator 0 Threshold Range.

0 (LOW): Set the comparator 0 threshold to the low range (0 V to VIO/8 in 48 steps).

1 (FULL): Set the comparator 0 threshold to a full range (0 V to VIO in 64 steps).

CMP1FTH

LC Comparator 1 Fine Threshold.

CMP1CTH

LC Comparator 1 Coarse Threshold.

CMP1THR

LC Comparator 1 Threshold Range.

0 (LOW): Set the comparator 1 threshold to the low range (0 V to VIO/8 in 48 steps).

1 (FULL): Set the comparator 1 threshold to a full range (0 V to VIO in 64 steps).

CMPLHYS

LC Comparator Low-side Hysteresis.

0 (0_MV): Set both LC comparators to use 0 mV low-side hysteresis.

1 (5_MV): Set both LC comparators to use 5 mV low-side hysteresis.

2 (10_MV): Set both LC comparators to use 10 mV low-side hysteresis.

3 (20_MV): Set both LC comparators to use 20 mV low-side hysteresis.

CMPHHYS

LC Comparator High-side Hysteresis.

0 (0_MV): Set both LC comparators to use 0 mV high-side hysteresis.

1 (5_MV): Set both LC comparators to use 5 mV high-side hysteresis.

2 (10_MV): Set both LC comparators to use 10 mV high-side hysteresis.

3 (20_MV): Set both LC comparators to use 20 mV high-side hysteresis.

CMPMD

LC Comparator Mode.

0 (5_US): Mode 0 (slowest response time, lowest power consumption).

1 (1_US): Mode 1.

2 (400_NS): Mode 2.

3 (200_NS): Mode 3 (fastest response time, highest power consumption).

CMP0CNT1EN

LC Comparator 0 to Count 1 Enable.

0 (DISABLED): Use LC comparator 0 as an input to counter 0 and LC comparator 1 as an input to counter 1.

1 (ENABLED): Use LC comparator 0 as an input to both counter 0 and counter 1.

FCMP0EN

Force LC Comparator 0 On Enable.

0 (DISABLED): Hardware automatically turns LC comparator 0 on and off.

1 (ENABLED): Force LC comparator 0 always on.

FCMP1EN

Force LC Comparator 1 On Enable.

0 (DISABLED): Hardware automatically turns LC comparator 1 on and off.

1 (ENABLED): Force LC comparator 1 always on.